9041086
Airflow Aventa AV100T 4 inch In-Line Fan with Timer, Mixed Flow
This is the Aventa 4 inch mixed flow extractor fan, in-line high performance fan with 2 speed operation. Adjustable timer model. Suitable for use with ducting and ideal for bathrooms, en-suites, shower rooms, utilities and kitchen.
Features
Aventa 100mm – Mixed flow fan fan Quiet and powerful, high performance up to 187 m3/hr.
Two speed operation with basic and timer models.
Ductable up to 6m and supplied with a mounting bracket.
Aventa 100mm in-line mixed flow fans are available in high-performance two speed versions.
They are less bulky than large in-line centrifugal fans and can be installed in loft spaces or service shafts.
This range is specially designed for residential applications requiring remote extraction.
It is also supplied with a mounting bracket for quick and easy installation on wooden joists and panels.
The inlet/outlets are compatible with flexible and rigid pipe runs up to 3m either side of the fan (6m).
The units operate manually from an (optional) three position switch (off/low/high) or with adjustable timer version (1 to 20 minutes)
Application
The Aventa in-line 100mm fans are suitable for removing damp moist air, odours and airborne pollutants from bathrooms, en-suites, shower rooms, utilities, kitchen and other internal living spaces without windows or natural ventilation.
Technical Specs
- Quiet and powerful mixed flow fan for use with up to 6m ducting
- 2 speed operation with basic switching or adjustable timer models
- High performance up to 187 m3/hr
- Remote mounting in lofts and cupboards
- Double-up – Two fans in series – double the pressure
- Two fans in parallel – double the flow
- Thermally protected motor
- Complies with the latest Building Regulations ADF 2006
- Mounting bracket supplied with a range of optional ventilation accessories
- 3 Year "no quibble" guarantee
- Quality assured to ISO9001
Customers Also Purchased (2)
Product Information
The Airflow Aventa AV100T (part number 9041086) is a 100mm mixed flow in-line fan with a built-in adjustable run-on timer. It fits within 100mm ducting, so the fan can sit in a loft or ceiling void away from the room it serves. This keeps noise in the room low and suits bathrooms, en-suites, shower rooms, toilets and utility rooms.
The mixed flow design combines the pressure of a centrifugal fan with the airflow of an axial fan, so it copes better with longer duct runs than a basic axial unit. The fan has two speeds, normal and boost, with airflow of 145 m³/h and 187 m³/h. The body detaches from its mounting base for easier installation and maintenance.
- Two speeds: 145 m³/h normal and 187 m³/h boost
- Adjustable run-on timer, triggered by a switched live
- IPX4 rated and Class II double insulated
- Mounts horizontally or vertically (vertical needs a condensation trap)
- Low noise of 27 dB(A) at 3m on normal speed
Airflow states it is compliant with Approved Document F of the Building Regulations. Covered by the manufacturer's warranty.
Specifications
| Model / part number | AV100T / 9041086 |
|---|---|
| Duct size | 100mm (4 inch) |
| Airflow (normal / boost) | 145 / 187 m³/h (40 / 52 l/s) |
| Power (normal / boost) | 21W / 33W |
| Noise at 3m (normal / boost) | 27 / 36 dB(A) |
| Supply | 230V, 50Hz, single phase |
| IP rating | IPX4 |
| Electrical class | Class II |
| Dimensions (H x W x D) | 190 x 246 x 126 mm |
| Weight | 1.5kg |
| Controls | Two speed with adjustable run-on timer |
Product Details
| Brand | Airflow |
|---|---|
| Weight (kg) | 1.643000 |
Delivery Information
| Location | Shipping Method | Shipping Charges | Timescales |
|---|---|---|---|
| Mainland UK | Standard Delivery | £3.95 | 3-5 working days |
| Northern Ireland | Standard Delivery | £3.95 | Next working day on in-stock items ordered by 5pm |
| Republic of Ireland | Standard Delivery | £3.95 | Next working day on in-stock items ordered by 5pm |
Free delivery on orders over £30 (ex VAT).
* Please note that delivery prices and services may vary depending on other items in your basket and your exact delivery postcode. Find out more about our delivery services.
Cancellations and Returns
Meteor Electrical Limited will accept returns up until 14 days after dispatch date on the conditions
- The Goods are in all original packaging
- The materials contain all original documentation (instructions, manuals, warranties or any other literature)
- Product is deemed by our returns department to be in a re-sellable condition
All refunds are made to the same payment method used originally to place the order (e.g. VISA Card) - unless specifically requested otherwise.
Faulty Products
- Products that are faulty must be returned within the manufacturer’s warranty period.
- The complete product must be returned, unless previously agreed by Meteor Electrical in writing; incomplete items of parts may not be returned.
- Products within the manufacturers specific warranty period will be repaired, replaced, or a refund given at the discretion of the Manufacture.
Frequently Asked Questions
Yes. The fan is rated IPX4 and Airflow's instructions state it is suitable for Zone 2 in bathrooms, toilets, kitchens and utility rooms, but only when the circuit is protected by a 30mA RCD. In most installations the fan itself sits in the loft or ceiling void, with ducting run to a grille in the room. Always check the manufacturer's instructions and comply with current wiring regulations.
The fan starts when a switched live is applied to the LT terminal, usually from the light switch or a separate switch, and keeps running for the set overrun time once that supply is removed. The run-on time is set with a small adjuster marked T on the control board, turned clockwise to increase. An external 3A fused supply is required. Check the manufacturer's instructions for wiring diagrams.
Yes. The Aventa can be fitted horizontally or vertically. Airflow's instructions call for a condensation trap when it is mounted vertically, to stop moisture running back into the fan. Follow the airflow arrow on the fan body so it extracts in the correct direction. Rigid ducting gives the best performance, and flexible duct should be pulled out fully and kept free of tight bends.
Airflow advises keeping the fan away from direct heat sources and not installing it where the temperature can exceed 40°C. If the room it ventilates contains an open-flued fuel-burning appliance, take precautions to prevent back-flow of combustion gases. Installation should be carried out by a qualified electrician. Check the manufacturer's instructions for full guidance on location and ducting.